Pages


BOQ- Lay In Metal False Ceiling

👉 Lay In Metal False Ceiling
"Supply and installation of Metal Ceiling system 600x600 mm of 0.5 mm including necessary framing works, fasteners of an approved type. Finish shall be powder coated of 50-60 micron, RAL - 9003. Fire rating shall be “ Class I- Surface Spread of Flame rating” as specified by the fire consultant. The unit rate shall include the sealant to interfacing and making provision for light fixtures and other utilities."

👉 Lay In Perforated Metal False Ceiling
PERFORATED METAL PANEL CEILING Providing and installing suspended ceiling system at all levels with interlocking grid of size 1200x6000mm / 600x600mm ceiling module of size (1250x600) consisting of demountable infill units (size 1200x600x1.2mm) having 50mm gap at every 1200mm, gap covered with 82mm wide channel having flanges to hold ceiling panels. The panels and channels shall be made from 1.2mm thick GI sheet, punched and bent to shape. The panels shall have perforated area 30-40%. The ceiling shall be powder coated (PPC, 80micron) on exposed and unexposed surface with approved colour. The grid system shall include hangers and runners of size 50x50x3mm thick hot dip galvanised steel, fixed on soffit of slab with the help of stainless steel expansion fasteners of size 10x75mm (Tam Anchor), The ceiling system to include panels, hanging system including the cost of providing opening and electrical fittings/fixtures, secondary supporting system for opening and below cable tray and duct, access to maintenance, all complete as per requirement of Engineer-in Charge.